As with any network build you will first need to figure out how you plan to segment you environment. This will help determine your VLAN and subnet needs. For this discussion we will keep things fairly simple: 3 VLANs.
- VLAN20 - server access on 10.0.20.0/24 (NAT at upstream firewall)
- VLAN172 - private network for backups on 172.16.0.0/24
- VLAN100 - private network for device management on 10.0.100.0/24
First thing that should be done is to configure an interface for the switch on another VLAN. This setup will provide another point of access to the switch when needed.
interface Vlan20
ip address 10.20.2.20 255.255.255.0
no ip route-cache
The IBM BladeCenter H in this example has 14 slot for blades with servers in the first 4 slots. To start I recommend shutting down all the ports for the unused blade slots. This will prevent you from potentially hosing your network when plugging in new servers.
ciscoswitch# conf termNext configure the port channels that will connect to the external 3750 switches. Lets assume we are working with the model illustrated in Figure 1. The main difference for setting up is that 2 x 2 port portchannels would be created rather than a 1 x 4 port portchannel as in this example. The external ports for the Cisco blade switch are numbered 17-20. (Notice ports 15 and 16 are skipped? These ports are for the internal connectivity between the management modules and the blade switches.) The following show a sample config for a port-channel using ports 17-20.
ciscoswitch(config)# int range gi0/4-14
ciscoswitch(config-if)# shut
interface Port-channel6
switchport trunk allowed vlan 20,30,172
switchport mode trunk
switchport nonegotiate
link state group 1 upstream
!
...
!
interface GigabitEthernet0/17
description To-3750-Top-25
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 20,172
switchport mode trunk
switchport nonegotiate
channel-group 6 mode active
spanning-tree link-type point-to-point (Recommended for rapid-PVST+ mode only)
!
interface GigabitEthernet0/18
description To-3750-Top-26
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 20,172
switchport mode trunk
switchport nonegotiate
channel-group 6 mode active
spanning-tree link-type point-to-point
!
interface GigabitEthernet0/19
description To-3750-Top-27
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 20,172
switchport mode trunk
switchport nonegotiate
channel-group 6 mode active
spanning-tree link-type point-to-point
!
interface GigabitEthernet0/20
description To-3750-Top-28
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 20,172
switchport mode trunk
switchport nonegotiate
channel-group 6 mode active
spanning-tree link-type point-to-point
...
A matching config will need to be created on the 3750 (top location, ports 25-28) to complete the port-channel. The 3750 config should not include the link state group 1 upstream statement in the port-channel config though. The reason will be explained shortly.
Now we are ready to configure the ports connecting the servers. For this example we are using a standar IBM HS21 blade that has two NICs, one to each blade switch. I want high availability to these servers but also need to connect to two different subnets. To accomplish this, configure the ports are trunks that have access to both VLANs. On the servers using the NIC vendor's teaming software (Windows) or NIC Bonding and 802.1q Tagging (Linux) to create virtual interfaces built from NIC pairs that pass VLAN tagged traffic.
The following is an example of the blade switch config for ports 1-4.
interface GigabitEthernet0/1The most important part of this config is the statement link state group 1 downstream. This statement is paired with the upstream statement in the port-channel config. What this does is monitor the status of the port-channel. If the entire port-channel goes down (i.e. all 4 links are lost, perhaps to a 3750 failure), all of the ports in group 1 down stream will go into shutdown mode. Why would I want to do this? At any one time, the teamed NICs of the servers may be passing traffic across either switch. Which switches and how much traffic depends on if teaming mode is load balancing or failover. Teaming/bonding monitors the NIC health at layer 2. Without the link state changes, the teaming software will not see any change in the upstream connecitivity and continue to pass traffic through this port. This will result in intermittent connectivity (load balancing method) or possibly complete loss of connectivity (failover method) to the server. With the link state groups set up correctly, the server may only experience a few dropped pings at worst.
description blade1
switchport trunk allowed vlan 20,172
switchport mode trunk
link state group 1 downstream
spanning-tree portfast trunk
spanning-tree bpdufilter enable
!
interface GigabitEthernet0/2
description blade2
switchport trunk allowed vlan 20,172
switchport mode trunk
link state group 1 downstream
spanning-tree portfast trunk
spanning-tree bpdufilter enable
!
interface GigabitEthernet0/3
description blade3
switchport trunk allowed vlan 20,172
switchport mode trunk
link state group 1 downstream
spanning-tree portfast trunk
spanning-tree bpdufilter enable
!
interface GigabitEthernet0/4
description blade4
switchport trunk allowed vlan 20,172
switchport mode trunk
link state group 1 downstream
spanning-tree bpdufilter enable
!
0 comments: